Príloha č. 7
Bezpečné vzdialenosti od zdrojov vysokofrekvenčnej energie
a) od vysielačov s frekvenciou 1,5-0,3 MHz (vlnové dĺžky 200-1000 m)
+-----------+-----------------------------------------------------------------------------------+
| | Bezpečný prúd elektrických roznecovadiel |
| +-------------+-------------+-------------+-------------+-------------+-------------+
| Výkon | 0,18 A | 0,45 A | 1 A | 1,5 A | 4 A | 5 A |
| vysielača +-------------+-------------+-------------+-------------+-------------+-------------+
| (kW) | Bezpečné vzdialenosti v metroch |
| +-------------+-------------+-------------+-------------+-------------+-------------+
| | A B | A B | A B | A B | A B | A B |
+-----------+-------------+-------------+-------------+-------------+-------------+-------------+
| 5 | 350 250 | 200 200 | 100 100 | 100 100 | 100 100 | 100 100 |
| 10 | 500 250 | 300 200 | 100 100 | 100 100 | 100 100 | 100 100 |
| 25 | 800 400 | 500 250 | 200 100 | 150 100 | 100 100 | 100 100 |
| 50 | 1200 600 | 700 350 | 300 150 | 200 100 | 100 100 | 100 100 |
| 100 | 2000 1000 | 1500 750 | 500 250 | 300 150 | 130 100 | 100 100 |
| 200 | 3000 1500 | 2400 1200 | 700 350 | 500 250 | 200 120 | 150 100 |
| 500 | 5000 2500 | 3000 1500 | 1000 500 | 800 400 | 350 190 | 300 150 |
| 750 | 6000 3000 | 4000 2000 | 1300 650 | 1000 500 | 400 200 | 360 180 |
| 1000 | 7200 3600 | 4600 2300 | 1500 750 | 1200 600 | 460 230 | 420 210 |
| 1500 | 8500 4250 | 5600 2800 | 1800 900 | 1400 700 | 560 280 | 520 260 |
+-----------+-------------+-------------+-------------+-------------+-------------+-------------+
A - bezpečná vzdialenost (m), ktorá platí pre výškový rozdiel roznetného okruhu od 10 do 20 m
B - bezpečná vzdialenosť (m), ktorá platí pre výškový rozdiel roznetného okruhu do 10 m
Pri väčšom výškovom rozdiele ako 20 m platí dvojnásobok hodnôt A.
b) od vysielačov s frekvenciou 30-1,5 MHz (vlnové dĺžky 10-200 m)
+-----------+-----------------------------------------------------------------------------------+
| | Bezpečný prúd elektrických roznecovadiel |
| +-------------+-------------+-------------+-------------+-------------+-------------+
| Výkon | 0,18 A | 0,45 A | 1 A | 1,5 A | 4 A | 5 A |
| vysielača +-------------+-------------+-------------+-------------+-------------+-------------+
| (kW) | Bezpečné vzdialenosti v metroch |
+-----------+-------------+-------------+-------------+-------------+-------------+-------------+
| 1 | 300 | 150 | 100 | 100 | 100 | 100 |
| 5 | 750 | 300 | 150 | 100 | 100 | 100 |
| 10 | 1000 | 400 | 200 | 100 | 100 | 100 |
| 50 | 2500 | 1000 | 500 | 250 | 120 | 100 |
| 100 | 3000 | 1500 | 600 | 300 | 170 | 150 |
| 200 | 4500 | 2000 | 900 | 450 | 225 | 200 |
| 500 | 7500 | 3000 | 1500 | 750 | 350 | 300 |
| 750 | 9000 | 4000 | 1800 | 900 | 380 | 340 |
| 1000 | 10500 | 4800 | 2100 | 1100 | 470 | 400 |
| 1500 | 12000 | 5500 | 2500 | 1250 | 550 | 450 |
+-----------+-------------+-------------+-------------+-------------+-------------+-------------+
c) od VKV a televíznych vysielačov
+-----------+-----------------------------------------------------------------------------------+
| | Bezpečný prúd elektrických roznecovadiel |
| +-------------+-------------+-------------+-------------+-------------+-------------+
| Výkon | 0,18 A | 0,45 A | 1 A | 1,5 A | 4 A | 5 A |
| vysielača +-------------+-------------+-------------+-------------+-------------+-------------+
| (kW) | Bezpečné vzdialenosti v metroch |
+-----------+-------------+-------------+-------------+-------------+-------------+-------------+
| 1 | 100 | 50 | 50 | 50 | 50 | 50 |
| 5 | 150 | 50 | 50 | 50 | 50 | 50 |
| 10 | 200 | 100 | 50 | 50 | 50 | 50 |
| 50 | 450 | 200 | 100 | 50 | 50 | 50 |
| 100 | 600 | 250 | 150 | 50 | 50 | 50 |
| 200 | 900 | 350 | 200 | 100 | 50 | 50 |
| 500 | 1500 | 600 | 300 | 150 | 100 | 100 |
| 1000 | 2000 | 800 | 400 | 200 | 100 | 100 |
| 1500 | 2500 | 1000 | 500 | 250 | 125 | 110 |
+-----------+-------------+-------------+-------------+-------------+-------------+-------------+
d) od rádiostaníc VKV (dispečerských, prenosných a pod.)
+------------------------+---------------+---------------+---------------+---------------+
| Výkon rádiostanice VKV | do 1 | 1 až 5 | 5 až 10 | 10 až 100 |
| (W) | | | | |
+------------------------+---------------+---------------+---------------+---------------+
| Bezpečná vzdialenosť | bez | 2 | 5 | 20 |
| (m) | obmedzenia *) | | | |
+------------------------+---------------+---------------+---------------+---------------+
*) platí len pre elektrické roznecovadlá s bezpečným prúdom vyšším ako 0,18 A
e) od rádiolokátorov
+---------------+--------+--------+--------+--------+--------+--------+
| Bezpečný prúd | | | | | | |
| elektrických | | | | | | |
| roznecovadiel | 0,18 A | 0,45 A | 1 A | 1,5 A | 4 A | 5 A |
| (A) | | | | | | |
+---------------+--------+--------+--------+--------+--------+--------+
| Bezpečné | | | | | | |
| vzdialenosti | 1000 | 400 | 200 | 100 | 50 | 40 |
| v metroch | | | | | | |
+---------------+--------+--------+--------+--------+--------+--------+
------------------------------------------------------------------